WHL-015 REV. 12.17.14
Figure 31 CH Set-Point Screen
Factory CH Set-Point is 180
o
F (82
o
C). CH Set-Point range is 86 180
o
F (30 82
o
C).
Turn the dial counterclockwise to lower and clockwise to raise the current CH set-point. After changing the temperature, press the
button to save the setting.
G. STORAGE MODE
Storage Mode indicates that the appliance is heating stored water in the internal storage tank. When Storage Mode is operating the
display appears as follows.
Figure 32 Storage Mode Screen
H. STATUS DISPLAY MODE
Status Display Mode will activate when the button is pressed and held for five seconds when the display panel is powered ON.
Figure 33 Status Mode Screens
Turn the dial counterclockwise and clockwise to scroll through the displayed parameters. To view parameter details, press the
button at the appropriate screen. Press the or buttons to leave the parameter.
Press the button again to return to Operation Mode.
To turn on Lock Mode, press the button at the d:Lc parameter. Turn the dial counterclockwise or clockwise to scroll On or Off.
Press the button to save the selection and return to the parameters.